Back to Search Start Over

Use and outcomes of subcutaneous implantable cardioverter-defibrillator (ICD) after transvenous ICD extraction: An analysis of current clinical practice and a comparison with transvenous ICD reimplantation.

Authors :
Viani, Stefano
Migliore, Federico
Tola, Gianfranco
PisanĂ², Ennio C.L.
Russo, Antonio Dello
Luzzi, Giovanni
Sartori, Paolo
Piro, Agostino
Rordorf, Roberto
Forleo, Giovanni Battista
Rago, Anna
Segreti, Luca
Bertaglia, Emanuele
Biffi, Mauro
Lovecchio, Mariolina
Valsecchi, Sergio
Diemberger, Igor
Bongiorni, Maria Grazia
Source :
Heart Rhythm; Apr2019, Vol. 16 Issue 4, p564-571, 8p
Publication Year :
2019

Abstract

<bold>Background: </bold>The subcutaneous implantable cardioverter-defibrillator (S-ICD) does not require the insertion of any leads into the cardiovascular system.<bold>Objective: </bold>The aims of the study were to describe current practice and to measure outcomes associated with S-ICD or standard single-chamber transvenous ICD (TV-ICD) use after TV-ICD explantation.<bold>Methods: </bold>We analyzed all consecutive patients who underwent transvenous extraction of an ICD and subsequent implantation of an S-ICD or a single-chamber TV-ICD at 12 Italian centers from 2011 to 2017.<bold>Results: </bold>A total of 229 patients were extracted and subsequently reimplanted with an S-ICD (90; 39%) or a single-chamber TV-ICD (139; 61%). S-ICD implantation increased from 9% in 2011 to 85% in 2017 (P < .001). Patients reimplanted with an S-ICD were younger (53 ± 13 years vs 60 ± 18 years; P = .011) and more frequently had undergone extraction owing to infection (73% vs 52%; P < .001). The rates of complications at follow-up were comparable between groups (hazard ratio 0.97; 95% confidence interval 0.49-1.92; P = .940). No lead failures, systemic infections, or system-related deaths occurred in the S-ICD group. In the TV-ICD group, 1 lead fracture occurred and 2 systemic infections were reported, resulting in death in 1 case. In the S-ICD group, the rate of complications was lower when the generator was positioned in a sub- or intermuscular pocket (hazard ratio 0.21; 95% confidence interval 0.05-0.87; P = .048).<bold>Conclusion: </bold>Our results show an increasing use of S-ICD over the years in patients undergoing TV-ICD explantation. An S-ICD is preferably adopted in young patients, mostly in the case of infection. The complication rate was comparable between groups and decreased when a sub- or intermuscular S-ICD generator position was adopted. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15475271
Volume :
16
Issue :
4
Database :
Supplemental Index
Journal :
Heart Rhythm
Publication Type :
Academic Journal
Accession number :
135438472
Full Text :
https://doi.org/10.1016/j.hrthm.2018.10.026