Analysis of an R744 typical booster configuration, an R744 parallel-compressor booster configuration and an R717/R744 cascade refrigeration system for retail food applications. Part 1: Thermodynamic analysis.

Authors :
Amaris, Carlos
Tsamos, Konstantinos M.
Tassou, Savvas A
Source :
Energy Procedia; Mar2019, Vol. 161, p259-267, 9p
Publication Year :
2019

Abstract

Abstract In this paper, the performances of a typical R744 booster configuration, a R744 parallel-compressor booster refrigeration system, and a R717/R744 cascade system configuration are presented based on the 1<superscript>st</superscript> and 2<superscript>nd</superscript> law of thermodynamics, for food retail applications. The results for a supermarket application with a total 145 kW cooling capacity show that the typical booster system and parallel-compressor booster system have better performances than the cascade system. However, for convenience store applications with 30 kW total cooling capacity the cascade system shows better performance beyond 26 °C ambient temperature which limits the applications of the cascade system for low capacity systems and the parallel refrigeration system solution appears to be a better option. In addition, the most critical components of each system based on the 2<superscript>nd</superscript> law are identified in this paper. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
18766102
Volume :
161
Database :
Supplemental Index
Journal :
Energy Procedia
Publication Type :
Academic Journal
Accession number :
135399280
Full Text :
https://doi.org/10.1016/j.egypro.2019.02.090