Back to Search
Start Over
Evaluation of a High Concentrated Contrast Media Injection Protocol in Combination with Low Tube Current for Dose Reduction in Coronary Computed Tomography Angiography: A Randomized, Two-center Prospective Study.
- Source :
- Academic Radiology; Dec2017, Vol. 24 Issue 12, p1482-1490, 9p
- Publication Year :
- 2017
-
Abstract
- <bold>Rationale and Objectives: </bold>The study aimed to prospectively evaluate the radiation dose reduction potential and image quality (IQ) of a high-concentration contrast media (HCCM) injection protocol in combination with a low tube current (mAs) in coronary computed tomography angiography.<bold>Materials and Methods: </bold>Eighty-one consecutive patients (mean age: 62 years; 34 females; body mass index: 18-31) were included and randomized-assigned into two groups. All computed tomography (CT) examinations were performed in two groups with the same tube voltage (100 kV), flow rate of contrast medium (5.0 mL/s), and iodine dose (22.8 g). An automatic mAs and low concentration contrast medium (300 mgI/mL) were used in group A, whereas effective mAs was reduced by a factor 0.6 along with HCCM (400 mgI/mL) in group B. Radiation dose was assessed (CT dose index [CTDIvol] and dose length product), and vessel-based objective IQ for various regions of interest (enhancement, noise, signal-to-noise ratio, and contrast-to-noise ratio), subjective IQ, noise, and motion artifacts were analyzed overall and vessel-based with a 5-point Likert scale.<bold>Results: </bold>The CT attenuation of coronary arteries and image noise in group B were significantly higher than those in group A (ranges: 507.5-548.1 Hounsfield units vs 407.5-444.5 Hounsfield units; and 20.3 ± 8.6 vs 17.7 ± 8.0) (P ≤ 0.0166). There was no significant difference between the two groups in signal-to-noise ratio, contrast-to-noise ratio, and subjective IQ of coronary arteries (29.4-31.7, 30.0-37.0, and medium score of 5 in group A vs 29.4-32.4, 27.7-36.3, and medium score of 5 in group B, respectively, P ≥ 0.1859). Both mean CTDIvol and dose length product in group B were 58% of those of group A.<bold>Conclusions: </bold>HCCM combined with low tube current allows dose reduction in coronary computed tomography angiography and does not compromise IQ. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10766332
- Volume :
- 24
- Issue :
- 12
- Database :
- Supplemental Index
- Journal :
- Academic Radiology
- Publication Type :
- Academic Journal
- Accession number :
- 126636283
- Full Text :
- https://doi.org/10.1016/j.acra.2017.07.001