Quantitative Analysis of Trace Heavy Elements in Geological Samples Utilizing High-energy (116 keV) Synchrotron Radiation X-ray Fluorescence Analysis for Forensic Investigation.

Authors :
Willy Shun Kai Bong
Izumi Nakai
Shunsuke Furuya
Hiroko Suzuki
Yoshinari Abe
Keiichi Osaka
Takuya Matsumoto
Masayoshi Itou
Noboru Imai
Toshio Ninomiya
Source :
Chemistry Letters; 11/5/2011, Vol. 40 Issue 11, p1310-1312, 3p
Publication Year :
2011

Abstract

High-energy (116 keV) synchrotron radiation X-ray fluorescence analysis has for the first time been applied to the quantitative analysis of trace heavy elements of geological samples. Calibration curves for the determination of trace heavy elements were obtained by measuring 7 reference rock samples and showed good linearity because of the high penetrating power of the high-energy X-rays. It is found that this method is suitable for rapid and nondestructive quantitative characterization of trace heavy elements in trace amount of soil samples for forensic investigation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03667022
Volume :
40
Issue :
11
Database :
Supplemental Index
Journal :
Chemistry Letters
Publication Type :
Academic Journal
Accession number :
121551991
Full Text :
https://doi.org/10.1246/cl.2011.1310