Experimental Research on Identification of Ground-borne Noise from Subway Lines Based on Partial Coherence Analysis.

Authors :
Li, Qiutong
Luo, Y.
Liu, Y.
Source :
Procedia Engineering; 2016, Vol. 144, p1150-1157, 8p
Publication Year :
2016

Abstract

The definition of how ground-borne noise is radiated into rooms in surrounding buildings due to underground subway lines is diverse in different countries, especially in the dominant frequency range. In the present paper, a set of field tests were carried out in Suzhou city, China to obtain ground vibration induced by subway vehicles and radiated noise in buildings. Preliminary analysis of frequency range is 1-300 Hz based on the strength of frequency domain analysis of the ground-borne vibration and noise and attenuation of vibration along propagation path. Furthermore, the ground-borne noise is recognized from the measured data by partial coherence function. Based on this theory, the contributions of different vibration sources to the noise are distinguished. The analyzed result shows that the recognized dominant frequency range of the ground-borne noise is between 20∼310 Hz. This research also indicates a difference of A-weighted sound levels between the tested result and contrasting criterions. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
18777058
Volume :
144
Database :
Supplemental Index
Journal :
Procedia Engineering
Publication Type :
Academic Journal
Accession number :
115678116