Aortic Dilation in Bicuspid Aortic Valve Disease.

Authors :
Bissell, Malenka M.
Hess, Aaron T.
Biasiolli, Luca
Glaze, Steffan J.
Loudon, Margaret
Pitcher, Alex
Davis, Anne
Prendergast, Bernard
Markl, Michael
Barker, Alex J.
Neubauer, Stefan
Myerson, Saul G.
Source :
Circulation: Cardiovascular Imaging; Jul2013, Vol. 6 Issue 4, p499-507, 9p
Publication Year :
2013

Abstract

Ascending aortic dilation is important in bicuspid aortic valve (BAV) disease, with increased risk of aortic dissection. We used cardiovascular MR to understand the pathophysiology better by examining the links between 3-dimensional flow abnormalities, aortic function, and aortic dilation.A total of 142 subjects underwent cardiovascular MR (mean age, 40 years; 95 with BAV, 47 healthy volunteers). Patients with BAV had predominantly abnormal right-handed helical flow in the ascending aorta, larger ascending aortas (18.3±3.3 versus 15.2±2.2 mm/m<superscript>2</superscript>; P<0.001), and higher rotational (helical) flow (31.7±15.8 versus 2.9±3.9 mm<superscript>2</superscript>/s; P<0.001), systolic flow angle (23.1°±12.5° versus 7.0°±4.6°; P<0.001), and systolic wall shear stress (0.85±0.28 versus 0.59±0.17 N/m<superscript>2</superscript>; P<0.001) compared with healthy volunteers. BAV with right-handed flow and right-non coronary cusp fusion (n=31) showed more severe flow abnormalities (rotational flow, 38.5±16.5 versus 27.8±12.4 mm<superscript>2</superscript>/s; P<0.001; systolic flow angle, 29.4°±10.9° versus 19.4°±11.4°; P<0.001; in-plane wall shear stress, 0.64±0.23 versus 0.47±0.22 N/m<superscript>2</superscript>; P<0.001) and larger aortas (19.5±3.4 versus 17.5±3.1 mm/m<superscript>2</superscript>; P<0.05) than right-left cusp fusion (n=55). Patients with BAV with normal flow patterns had similar aortic dimensions and wall shear stress to healthy volunteers and younger patients with BAV showed abnormal flow patterns but no aortic dilation, both further supporting the importance of flow pattern in the pathogenesis of aortic dilation. Aortic function measures (distensibility, aortic strain, and pulse wave velocity) were similar across all groups.Flow abnormalities may be a major contributor to aortic dilation in BAV. Fusion type affects the severity of flow abnormalities and may allow better risk prediction and selection of patients for earlier surgical intervention. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
19419651
Volume :
6
Issue :
4
Database :
Supplemental Index
Journal :
Circulation: Cardiovascular Imaging
Publication Type :
Academic Journal
Accession number :
110162016
Full Text :
https://doi.org/10.1161/CIRCIMAGING.113.000528