HCN212-channel biological pacemakers manifesting ventricular tachyarrhythmias are responsive to treatment with I(f) blockade.
- Source :
- Heart Rhythm; Feb2008, Vol. 5 Issue 2, p282-288, 7p
- Publication Year :
- 2008
-
Abstract
- <bold>Background: </bold>A potential concern about biological pacemakers is their possible malfunction, which might create ventricular tachycardias (VTs).<bold>Objective: </bold>The purpose of this study was to test our hypothesis that should VTs complicate implantation of HCN-channel-based biological pacemakers, they would be suppressed by inhibitors of the pacemaker current, I(f).<bold>Methods: </bold>We created a chimeric channel (HCN212) containing the N- and C-termini of mouse HCN2 and the transmembrane region of mouse HCN1 and implanted it in HEK293 cells. Forty-eight hours later, in whole-cell patch clamp recordings, mean steady state block induced by 3 microM ivabradine (IVB) showed HCN1 = HCN212 > HCN2 currents. The HCN212 adenoviral construct was then implanted into the canine left bundle branch in 11 dogs. Complete AV block was created via radiofrequency ablation, and a ventricular demand electronic pacemaker was implanted (VVI 45 bpm). Electrocardiogram, 24-hour Holter monitoring, and pacemaker log record check were performed for 11 days.<bold>Results: </bold>All dogs developed rapid VT (>120 bpm, maximum rate = 285 +/- 37 bpm) at 0.9 +/- 0.3 days after implantation that persisted through 5 +/- 1 days. IVB, 1 mg/kg over 5 minutes, was administered during rapid VT, and three dogs received a second dose 24 hours later. While VT terminated with IBV in all instances within 3.4 +/- 0.6 minutes, no effect of IVB on sinus rate was noted.<bold>Conclusion: </bold>We conclude that (1) I(f)-associated tachyarrhythmias-if they occur with HCN-based biological pacemakers-can be controlled with I(f)-inhibiting drugs such as IVB; (2) in vitro, IVB appears to have a greater steady state inhibiting effect on HCN1 and HCN212 isoforms than on HCN4; and (3) VT originating from the HCN212 injection site is suppressed more readily than sinus rhythm. This suggests a selectivity of IVB at the concentration attained for ectopic over HCN4-based pacemaker function. This might confer a therapeutic benefit. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 15475271
- Volume :
- 5
- Issue :
- 2
- Database :
- Supplemental Index
- Journal :
- Heart Rhythm
- Publication Type :
- Academic Journal
- Accession number :
- 105758531
- Full Text :
- https://doi.org/10.1016/j.hrthm.2007.09.028