Back to Search Start Over

Hygrothermal behavior of a massive wall with interior insulation during wetting.

Authors :
Guizzardi, M.
Derome, D.
Vonbank, R.
Carmeliet, J.
Source :
Building & Environment; Jul2015, Vol. 89, p59-71, 13p
Publication Year :
2015

Abstract

To improve the energy efficiency of historical buildings, the introduction of an interior insulation is often the only possible solution in order to preserve their valuable external facades. However, this intervention changes the wall hygrothermal conditions and can negatively affect its hygrothermal performance. Furthermore, interior insulation is often difficult to apply due to practical problems of irregularities in geometry and heterogeneity of materials. A newly developed high insulating render is used as interior insulation on a masonry test wall and is exposed to controlled but severe wetting conditions, while the hygrothermal parameters in its different components have been recorded. In addition to provide a well-documented dataset for model validation, this investigation highlights the hygrothermal behavior of a masonry wall internally insulated with a new developed highly insulating render. The experimental work described in the present paper is designed in order to record data to be used for the validation of a numerical model for the parametric study of the hygrothermal behavior of internally insulated masonry walls. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
03601323
Volume :
89
Database :
Supplemental Index
Journal :
Building & Environment
Publication Type :
Academic Journal
Accession number :
102160992
Full Text :
https://doi.org/10.1016/j.buildenv.2015.01.034