Back to Search
Start Over
Local dynamic characteristics of PZT impedance interface on tendon anchorage under prestress force variation.
- Source :
- Smart Structures & Systems; Feb2015, Vol. 15 Issue 2, p375-393, 19p
- Publication Year :
- 2015
-
Abstract
- In this study, local dynamic characteristics of mountable PZT interfaces are numerically analyzed to verify their feasibility on impedance monitoring of the prestress-loss in tendon anchorage subsystems. Firstly, a prestressed tendon-anchorage system with mountable PZT interfaces is described. Two types of mountable interfaces which are different in geometric and boundary conditions are designed for impedance monitoring in the tendon-anchorage subsystems. Secondly, laboratory experiments are performed to evaluate the impedance monitoring via the two mountable PZT interfaces placed on the tendon-anchorage under the variation of prestress forces. Impedance features such as frequency-shifts and root-mean-square-deviations are quantified for the two PZT interfaces. Finally, local dynamic characteristics of the two PZT interfaces are numerically analyzed to verify their perfonuances on impedance monitoring at the tendon-anchorage system. For the two PZT interfaces, the relationships between structural parameters and local vibration responses are examined by modal sensitivity analyses. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 17381584
- Volume :
- 15
- Issue :
- 2
- Database :
- Supplemental Index
- Journal :
- Smart Structures & Systems
- Publication Type :
- Academic Journal
- Accession number :
- 102133148
- Full Text :
- https://doi.org/10.12989/sss.2015.15.2.375