Back to Search Start Over

Design of the radiation shielding for the time of flight enhanced diagnostics neutron spectrometer at Experimental Advanced Superconducting Tokamak.

Authors :
Du, T. F.
Chen, Z. J.
Peng, X. Y.
Yuan, X.
Zhang, X.
Gorini, G.
Nocente, M.
Tardocchi, M.
Hu, Z. M.
Cui, Z. Q.
Xie, X. F.
Ge, L. J.
Hu, L. Q.
Zhong, G. Q.
Lin, S. Y.
Wan, B. N.
Li, X. Q.
Zhang, G. H.
Chen, J. X.
Fan, T. S.
Source :
Review of Scientific Instruments; 2014, Vol. 85 Issue 11, p1-3, 3p
Publication Year :
2014

Abstract

A radiation shielding has been designed to reduce scattered neutrons and background gamma-rays for the new double-ring Time Of Flight Enhanced Diagnostics (TOFED). The shielding was designed based on simulation with the Monte Carlo code MCNP5. Dedicated model of the EAST tokamak has been developed together with the emission neutron source profile and spectrum; the latter were simulated with the Nubeam and GENESIS codes. Significant reduction of background radiation at the detector can be achieved and this satisfies the requirement of TOFED. The intensities of the scattered and direct neutrons in the line of sight of the TOFED neutron spectrometer at EAST are studied for future data interpretation. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00346748
Volume :
85
Issue :
11
Database :
Complementary Index
Journal :
Review of Scientific Instruments
Publication Type :
Academic Journal
Accession number :
99683233
Full Text :