Back to Search
Start Over
Fixation techniques for the anterior cruciate ligament reconstruction: early follow-up. A systematic review of level I and II therapeutic studies.
- Source :
- Musculoskeletal Surgery; Dec2014, Vol. 98 Issue 3, p179-187, 9p
- Publication Year :
- 2014
-
Abstract
- The purpose of our study was that to systematically review the fixation techniques for the ACL reconstruction and associated clinical outcomes at the early follow-up. Systematic search on three electronic databases (Cochrane register, Medline and Embase) of fixation devices used for primary ACL reconstruction with doubled semitendinosus and gracilis and bone-patellar tendon-bone autografts in randomized clinical trials of level I and II of evidence published from January 2001 to December 2011. Therapeutic studies collected were with a minimum 12-month follow-up, and the clinical outcomes were evaluated by at least one of International Knee Documentation Committee, Lysholm and Tegner functional scales and at least one of the following knee stability tests: arthrometric AP tibial translation, Lachman test and pivot-shift test. Nineteen articles met the inclusion criteria. At the femoral side cross-pin, metallic interference screw, bioabsorbable interference screw, and suspensory device were used in 32.3, 27.3, 24.8, 15.5 % of patients, respectively. At the tibial side fixation was achieved with metallic interference screw, bioabsorbable interference screw, screw and plastic sheath, screw post and cross-pin in 38.7, 31, 15.7, 12.8, and 1.7 % of patients, respectively. Side-to-side anterior-posterior tibial translation was 1.9 ± 0.9, 1.5 ± 0.9, 1.5 ± 0.8, 2.2 ± 0.4 mm for metallic interference screw, bioabsorbable screw, cross-pin and suspensory device, respectively. At least two-third of all the patients achieved good-to-excellent clinical outcomes. Rate of failure was 6.1, 3.3, 1.7 and 1.2 % for bioabsorbable interference screw, metallic interference screw, cross-pin and suspensory device, respectively. Clinical outcomes are good to excellent in almost two-third of the patients but several pitfalls that affect the current fixation techniques as graft tensioning such as graft-tunnel motion are still unaddressed. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 20355106
- Volume :
- 98
- Issue :
- 3
- Database :
- Complementary Index
- Journal :
- Musculoskeletal Surgery
- Publication Type :
- Academic Journal
- Accession number :
- 99516697
- Full Text :
- https://doi.org/10.1007/s12306-014-0338-8