Optimization of fundamental parameters in routine production of Y-hydroxyapatite for radiosynovectomy.

Authors :
Davarpanah, Mohammad
Khoshhosn, Hossein
Harati, Mohsen
Attar Nosrati, S.
Zoghi, Masoumeh
Mazidi, Mohammad
Ghannadi Maragheh, M.
Source :
Journal of Radioanalytical & Nuclear Chemistry; Oct2014, Vol. 302 Issue 1, p69-77, 9p, 1 Black and White Photograph, 1 Diagram, 5 Charts, 4 Graphs
Publication Year :
2014

Abstract

Hydroxyapatite was applied as a carrier adsorbing Y ions for Y-HA colloid production. The radiopharmaceutical colloid was prepared by adding an acidic solution of YCl to HA suspension in saline solution. Effective parameters on labeling of Y-HA were evaluated. Adsorption and cation-exchange properties were studied using inductively coupled plasma elemental analysis and N adsorption-desorption isotherm method. Radionuclidic purity was over 99.9 %. Labeling yield and radiochemical purity were >99 %. Radiochemical purity was evaluated also in human albumin for 7 days at 37 °C. Biodistribution studies have shown complete retention of injected radioactivity at the administration site up to 72 h. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02365731
Volume :
302
Issue :
1
Database :
Complementary Index
Journal :
Journal of Radioanalytical & Nuclear Chemistry
Publication Type :
Academic Journal
Accession number :
98148366
Full Text :
https://doi.org/10.1007/s10967-014-3326-4