The Development of in-situ Calibration Method for Divertor IR Thermography in ITER.
- Source :
- AIP Conference Proceedings; 2014, Vol. 1612, p153-156, 4p, 1 Color Photograph, 2 Diagrams, 4 Graphs
- Publication Year :
- 2014
-
Abstract
- For the development of the calibration method of the emissivity in IR light on the divertor plate in ITER divertor IR thermography system, the laboratory experiments have been performed by using IR instruments. The calibration of the IR camera was performed by the plane black body in the temperature of 100-600 degC. The radiances of the tungsten heated by 280 degC were measured by the IR camera without filter (2.5-5.1 μm) and with filter (2.95μim, 4.67 μm). The preliminary data of the scattered light of the laser of 3.34 |im that injected into the tungsten were acquired. [ABSTRACT FROM AUTHOR]