Back to Search Start Over

Direct Label-Free Electrical Immunodetection of Transplant Rejection Protein Biomarker in Physiological Buffer Using Floating Gate AlGaN/GaN High Electron Mobility Transistors.

Authors :
Tulip, Fahmida S.
Eteshola, Edward
Desai, Suchita
Mostafa, Salwa
Roopa, Subramanian
Evans, Boyd
Islam, Syed Kamrul
Source :
IEEE Transactions on NanoBioscience; Jun2014, Vol. 13 Issue 2, p138-145, 8p
Publication Year :
2014

Abstract

Monokine induced by interferon gamma (MIG/CXCL9) is used as an immune biomarker for early monitoring of transplant or allograft rejection. This paper demonstrates a direct electrical, label-free detection method of recombinant human MIG with anti-MIG IgG molecules in physiologically relevant buffer environment. The sensor platform used is a biologically modified GaN-based high electron mobility transistor (HEMT) device. Biomolecular recognition capability was provided by using high affinity anti-MIG monoclonal antibody to form molecular affinity interface receptors on short N-hydroxysuccinimide-ester functionalized disulphide (DSP) self-assembled monolayers (SAMs) on the gold sensing gate of the HEMT device. A floating gate configuration has been adopted to eliminate the influences of external gate voltage. Preliminary test results with the proposed chemically treated GaN HEMT biosensor show that MIG can be detected for a wide range of concentration varying from 5 ng/mL to 500 ng/mL. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
15361241
Volume :
13
Issue :
2
Database :
Complementary Index
Journal :
IEEE Transactions on NanoBioscience
Publication Type :
Academic Journal
Accession number :
96313064
Full Text :
https://doi.org/10.1109/TNB.2014.2318234