An ECT/ERT Dual-Modality Sensor for Oil-Water Two-phase Flow Measurement.
- Source :
- AIP Conference Proceedings; 2014, Vol. 1592, p3-9, 7p, 1 Color Photograph, 1 Diagram, 6 Graphs
- Publication Year :
- 2014
-
Abstract
- This paper presents a new sensor for ECT/ERT dual-modality system which can simultaneously obtain the permittivity and conductivity of the materials in the pipeline. Quasi-static electromagnetic fields are produced by the inner electrodes array sensor of electrical capacitance tomography (ECT) system. The results of simulation show that the data of permittivity and conductivity can be simultaneously obtained from the same measurement electrode and the fusion of two kinds of data may improve the quality of the reconstructed images. For uniform oil-water mixtures, the performance of designed dual-modality sensor for measuring the various oil fractions has been tested on representative data and the results of experiments show that the designed sensor broadens the measurement range compared to single modality. [ABSTRACT FROM AUTHOR]