Back to Search Start Over

Construction Challenges and Solutions in TAMU3, a 14 T Stress-Managed Nb3Sn Dipole.

Authors :
Holik, E. F.
Garrison, R.
Diaczenko, N.
Elliott, T.
Jaisle, A.
McInturff, A. D.
McIntyre, P.
Sattarov, A.
Source :
AIP Conference Proceedings; Jan2014, Vol. 1573, p1535-1542, 8p, 2 Color Photographs, 1 Diagram, 3 Charts, 6 Graphs
Publication Year :
2014

Abstract

The Accelerator Research Laboratory at Texas A&M University is nearing completion of a Nb3Sn dipole that incorporates stress management directly in its windings. The windings utilize graded-cross-section cable made from 54/61 (54 out of a 61 subelement hexagonal pattern) Restacked Rod Processed® Nb<subscript>3</subscript>Sn/Cu conductor and fine-filament S-2 glass fabric insulation. Coil heat treatment and associated differential expansions have brought about some tin leakage, highresistance electrical shorts, and coil gaps. TAMU3b impregnation successfully increased the coil-to-ground resistance. Quench protection in TAMU3 was simulated using QUENCH. The tests of TAMU3 should provide the first examination of stress management at field intensities greater than 12 T. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
1573
Database :
Complementary Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
94258017
Full Text :