Back to Search
Start Over
Application of JLab 12GeV Helium Refrigeration System for the FRIB Accelerator at MSU.
- Source :
- AIP Conference Proceedings; Jan2014, Vol. 1573, p323-328, 6p, 1 Diagram, 6 Charts, 1 Graph
- Publication Year :
- 2014
-
Abstract
- The planned approach to have a turnkey helium refrigeration system for the MSU-FRIB accelerator system, encompassing the design, fabrication, installation and commissioning of the 4.5-K refrigerator cold box(es), cold compression system, warm compression system, gas management, oil removal and utility/ancillary systems, was found to be cost prohibitive. Following JLab's suggestion, MSU-FRIB accelerator management made a formal request to evaluate the applicability of the recently designed 12GeV JLab cryogenic system for this application. The following paper will outline the findings and the planned approach for the FRIB helium refrigeration system. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 0094243X
- Volume :
- 1573
- Database :
- Complementary Index
- Journal :
- AIP Conference Proceedings
- Publication Type :
- Conference
- Accession number :
- 94257847
- Full Text :
- https://doi.org/10.1063/1.4860718