Back to Search Start Over

Optimization of ECR-breakdown and plasma discharge formation on T-10 tokamak, using X-mode second harmonic of ECR.

Authors :
Borshchegovskiy, A.
Dremin, M.
Il'in, V.
Kirneva, N.
Kislov, A.
Krupin, V.
Maltsev, S.
Pavlov, Y.
Petrov, D.
Roy, I.
Shelukhin, D.
Sokolov, M.
Source :
EPJ Web of Conferences; 2012, Issue 32, p02004-p.1-02004-p.6, 6p
Publication Year :
2012

Abstract

In order to obtain breakdown and suitable plasma parameters for low-voltage OH start-up, high level of EC-power was injected into T-10 tokamak. Input HF-power was varied in the range of 0.15-1.0 MW. Two HF-launcher systems with different output beams allowed to inject EC-waves with maximum power density 0.25 MW/cm² and 0.01 MW/cm². Dependence of breakdown time delay on HF-power was obtained. It was shown, that optimal plasma parameters were achieved in presence of plasma equilibrium currents I=3 kA (input HF-power=1.0 MW). Electron temperature Te=100/150 eV and electron density ne=5x10<superscript>12</superscript> cm<superscript>-3</superscript> was measured in these discharges. These parameters remained constant during full HF-pulse-length. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
21016275
Issue :
32
Database :
Complementary Index
Journal :
EPJ Web of Conferences
Publication Type :
Conference
Accession number :
84419766
Full Text :
https://doi.org/10.1051/epjconf/20123202004