Back to Search Start Over

Quantitative assessment of regional cerebral blood flow by dynamic susceptibility contrast-enhanced MRI, without the need for arterial blood signals.

Authors :
Enmi1, Jun-ichiro
Kudomi, Nobuyuki
Hayashi, Takuya
Yamamoto, Akihide
Iguchi, Satoshi
Moriguchi, Tetsuaki
Hori, Yuki
Koshino, Kazuhiro
Zeniya, Tsutomu
Shah, Nadim Jon
Yamada, Naoaki
Iida, Hidehiro
Source :
Physics in Medicine & Biology; 12/7/2012, Vol. 57 Issue 23, p7873-7892, 20p
Publication Year :
2012

Abstract

In dynamic susceptibility contrast-enhanced magnetic resonance imaging (DSC-MRI), an arterial input function (AIF) is usually obtained from a time- concentration curve (TCC) of the cerebral artery. This study was aimed at developing an alternative technique for reconstructing AIF from TCCs of multiple brain regions. AIF was formulated by a multi-exponential function using four parameters, and the parameters were determined so that the AIF curves convolved with a model of tissue response reproduced the measured TCCs for 20 regions. Systematic simulations were performed to evaluate the effects of possible error sources. DSC-MRI and positron emission tomography (PET) studies were performed on 14 patients with major cerebral artery occlusion. Cerebral blood flow (CBF) images were calculated from DSC-MRI data, using our novel method alongside conventional AIF estimations, and compared with those from <superscript>15</superscript>O-PET. Simulations showed that the calculated CBF values were sensitive to variations in the assumptions regarding cerebral blood volume. Nevertheless, AIFs were reasonably reconstructed for all patients. The difference in CBF values between DSC-MRI and PET was -2.2 ± 7.4 ml/100 g/min (r = 0.55, p < 0.01) for our method, versus -0.2 ± 8.2 ml/100 g/min (r = 0.47, p = 0.01) for the conventional method. The difference in the ratio of affected to unaffected hemispheres between DSCMRI and PET was 0.07 ± 0.09 (r = 0.82, p < 0.01) for our method, versus 0.07 ± 0.09 (r = 0.83, p < 0.01) for the conventional method. The contrasts in CBF images from our method were the same as those from the conventional method. These findings suggest the feasibility of assessing CBF without arterial blood signals. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00319155
Volume :
57
Issue :
23
Database :
Complementary Index
Journal :
Physics in Medicine & Biology
Publication Type :
Academic Journal
Accession number :
83883653
Full Text :
https://doi.org/10.1088/0031-9155/57/23/7873