Back to Search Start Over

Treatment of atrial fibrillation with an implantable atrial defibrillator — long term results.

Authors :
Geller, J.Christoph
Reek, Sven
Timmermans, Carl
Kayser, Torsten
Tse, Hung-Fat
Wolpert, Christian
Jung, Werner
Camm, A.John
Lau, Chu-Pak
Wellens, Hein J.J.
Klein, Helmut U.
Source :
European Heart Journal; 2003, Vol. 24 Issue 23, p2083-2089, 7p
Publication Year :
2003

Abstract

Objectives To evaluate the long-term outcome with an implantable atrial defibrillator (IAD) in patients with recurrent atrial fibrillation (AF).Background Maintenance of sinus rhythm using repeated internal cardioversion shocks has been shown to be effective and safe in short-term studies but long term follow-up is unknown.Methods Since 1995, 136 patients (30 women) with symptomatic, drug-refractory atrial fibrillation were implanted with an IAD (METRIX, InControl). This analysis was performed after a median of 40 (range 7–66) months after implantation.Results In 26 patients, the programmed mode was not documented during last follow-up, four patients had died. Of the remaining 106 patients (mean age 58±10, range 34 – 79 years), 39 were actively delivering therapy with the device, in 14 patients the device was used to monitor the arrhythmia but no shocks were delivered, and in 53 patients it was turned off or explanted. Increases in defibrillation thresholds (n=7), patient intolerance of multiple cardioversion shocks (n=15), and significant bradycardia requiring dual-chamber pacing (n=12) were the main reasons for discontinuation of therapy in addition to battery depletion (n=19). After explantation, efforts to maintain sinus rhythm were continued in 17 patients whereas rate control was attempted in 36 patients.Conclusions A strategy of maintaining sinus rhythm long-term with an IAD is feasible in a proportion of patients. However, patient selection is critical, and technical improvements (i.e. higher shock energies, dual-chamber pacing and additional preventive and anti-tachycardia pacing algorithms) are required to increase the number of patients having long term benefit, and frequent arrhythmia recurrences and patient intolerance to repeated cardioversion shocks remain a major limitation. [ABSTRACT FROM PUBLISHER]

Details

Language :
English
ISSN :
0195668X
Volume :
24
Issue :
23
Database :
Complementary Index
Journal :
European Heart Journal
Publication Type :
Academic Journal
Accession number :
80097558
Full Text :
https://doi.org/10.1016/j.ehj.2003.09.033