Back to Search Start Over

Measurement of airway resistance in anesthetized and paralyzed subjects: Proposal for evaluation of K values.

Authors :
Sakai, Takayuki
Yoshida, Hitoshi
Yano, Hirofumi
Takaori, Masuhiko
Source :
Journal of Anesthesia; Sep1988, Vol. 2 Issue 2, p139-145, 7p
Publication Year :
1988

Abstract

The effects of lung volume and respiratory airflow on airway resistance were studied in five anesthetized and paralyzed patients. Airway resistance measured during the inspiratory phase with intermittent constant airflow inflations decreased in inverse correlationship to increases in lung volume. Airway resistance measured during the expiratory phase with an airway interruption technique, on the other hand, increased with a linear relationship to the expiratory airflow as expressed by a function of =K+ KX. K, calculated from the values of airway resistance corresponding to three different airflows, was unaffected by intentional expiratory resistance loading. Thus, simultaneously with the measurement of airway resistance by this method, expiratory gas sampling with a Douglas bag can be done if necessary. Since the K value of the endotracheal tube used in this study (PorteX® I.D. 8 mm, length 26 cm) was quite high (5.0 cmHO·1·sec), depending on the airflow, the presence of the endotracheal tube strongly affected the measurement of airway resistance during general anesthesia. K measured by the above method, however, may be considered as the best way to evaluate the lower airway resistance independent of either lung volume or expiratory airflow. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09138668
Volume :
2
Issue :
2
Database :
Complementary Index
Journal :
Journal of Anesthesia
Publication Type :
Academic Journal
Accession number :
71058001
Full Text :
https://doi.org/10.1007/s0054080020139