Back to Search Start Over

Carotid artery recognition system: A comparison of three automated paradigms for ultrasound images.

Authors :
Molinari, Filippo
M. Meiburger, Kristen
Zeng, Guang
Acharya, U. Rajendra
Liboni, William
Nicolaides, Andrew
Suri, Jasjit S.
Source :
Medical Physics; Jan2012, Vol. 39 Issue 1, p378-391, 14p
Publication Year :
2012

Abstract

Purpose: The development of completely automated techniques for arterial wall segmentation and intima-media thickness measurement requires the recognition of the artery in the image frame. Conceptually, automated techniques can be thought of as the combination of two cascaded stages: artery recognition and wall segmentation. In this paper, the authors show three carotid artery recognition systems (CARS) that are fully automated. Methods: The first technique is based on a first-order derivative Gaussian edge analysis (CARSgd). The second method is based on an integrated approach (CARSia) that combines image feature extraction, fitting, and classification. The third strategy is based on signal analysis (CARSsa). The output of all the three paradigms provide tracing of the far adventitial (ADF). The authors validated CARSgd, CARSia, and CARSsa on a dataset of 365 longitudinal B-Mode carotid images, acquired by different sonographers. Performance evaluation of the carotid recognition process was done in three ways: (1) visual inspection by experts; (2) by measuring the Hausdorff distance (HD) between the automatic far adventitial (ADF) and the manually traced ADF, and (3) by measuring the HD between ADF and the lumen-intima (GTLI) and media-adventitia (GTMA) borders of the arterial walls. Results: The average HD between ADF and the manual ADF was 1.53 ± 1.51 mm for CARSgd, 1.82 ± 3.08 mm for CARSia, and 2.56 ± 2.89 mm for CARSsa. The average HD between GTLI and ADF for CARSgd, CARSia, and CARSsa were 2.16 ± 1.16 mm, 2.71 ± 2.89 mm, and 2.66 ± 1.52 mm, respectively. The average HD between ADF and GTMA for CARSgd, CARSia, and CARSsa were 1.54 ± 1.19 mm, 1.86 ± 2.66 mm, and 1.95 ± 1.64 mm, respectively. Considering a maximum distance of 50 pixels (about 3 mm), CARSgd showed an identification accuracy of 100%, CARSia of 92%, and CARSsa of 96%. These identification accuracies were confirmed by visual inspection. All the three systems work on MATLAB, Windows OS, and on a PC based cross platform medical application written in Java called ATHEROEDGEâ„¢ with 1 s per image. Conclusions: CARSgd showed very accurate ADF profiles coupled with a low computational burden and without the need for specific tuning. It can be thought of as a reference technique for carotid localization, to be used in automated intima-media thickness measurement strategies. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00942405
Volume :
39
Issue :
1
Database :
Complementary Index
Journal :
Medical Physics
Publication Type :
Academic Journal
Accession number :
70100022
Full Text :
https://doi.org/10.1118/1.3670373