Back to Search Start Over

Can the degree of retrograde diastolic flow in abnormal umbilical artery flow velocity waveforms predict pregnancy outcome?

Authors :
Brodszki, J
Hernandez-Andrade, E
Gudmundsson, S
Dubiel, M
Mandruzzato, G. P
Laurini, R
Maršál, K
Source :
Ultrasound in Obstetrics & Gynecology; Mar2002, Vol. 19 Issue 3, p229-234, 6p
Publication Year :
2002

Abstract

ABSTRACT Objective Reverse end-diastolic flow is the most pathological type of the umbilical artery flow velocity waveform. We aimed to investigate whether additional prognostic information can be obtained from umbilical artery waveforms in cases with reverse end-diastolic flow. Subjects and methods Umbilical artery Doppler velocity waveforms from 44 fetuses with reverse end-diastolic flow were analyzed and the following parameters measured: the highest amplitude and the area below the maximum velocity curve of forward and reverse flow (A, B and C, D, respectively) and the duration of forward and reverse flow (Tc and Td, respectively). Ratios A/B, C/D and Tc/Td were calculated. The cut-off values for A/B, C/D and Tc/Td with the best predictive values for perinatal death were established with the help of receiver operating characteristics curves. The three curves were compared with each other. Results Of the three ratios, A/B and C/D had the best capacity to predict perinatal death. Both ratios had acceptable sensitivities, specificities and positive predictive values. In this regard, A/B and C/D were comparable. The cut-off values for A/B and C/D were 4.3 and 4.52, respectively. Survivors had significantly higher A/B and C/D ratios than non-survivors (P = 0.0001 and 0.0003, respectively). Significantly more fetuses with A/B or C/D below the established cut-off values had pulsations in the venous system (P < 0.05). In fetuses with a gestational age ≤ 210 gestational days the survival rate was significantly higher in those with A/B or C/D above the cut-off values (P = 0.03 and 0.003, respectively). Conclusions The A/B or C/D ratio can be used for quantification of the reverse end-diastolic flow waveforms in the umbilical artery and may offer additional information to the evaluation of fetal condition. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
09607692
Volume :
19
Issue :
3
Database :
Complementary Index
Journal :
Ultrasound in Obstetrics & Gynecology
Publication Type :
Academic Journal
Accession number :
6354727
Full Text :
https://doi.org/10.1046/j.1469-0705.2002.00636.x