Abstract
- Details how a reciprocating Langmuir probe was used to measure density and temperature profiles, ion flow, and potential fluctuation levels from the lower divertor floor up to the X point on the DIII-D Tokamak. Mechanical design of the probe; Probe tip design; Measurements of physical parameters; Control and data acquisition.