Degradation Analysis of High Concentration Photovoltaic Module.
- Source :
- AIP Conference Proceedings; 10/14/2010, Vol. 1277 Issue 1, p256-259, 4p, 3 Black and White Photographs, 1 Diagram, 3 Charts, 4 Graphs
- Publication Year :
- 2010
-
Abstract
- The Institute of Nuclear Energy Research (INER) in Taiwan had established a 100 kW HCPV power generation system in October, 2007. After operating for 16 months, the optical-electro conversion efficiency of the system downgraded from 23.5% to 20.7%. This report analyzes the root causes of HCPV module efficiency degradation and provides some solutions to overcome the problems. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 0094243X
- Volume :
- 1277
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- AIP Conference Proceedings
- Publication Type :
- Conference
- Accession number :
- 54470045
- Full Text :
- https://doi.org/10.1063/1.3509205