Back to Search Start Over

Degradation Analysis of High Concentration Photovoltaic Module.

Authors :
Liang, Y. P.
Lin, K. H.
Shih, Z. H.
Hong, H. F.
Shin, H. Y.
Kuo, C. T.
Source :
AIP Conference Proceedings; 10/14/2010, Vol. 1277 Issue 1, p256-259, 4p, 3 Black and White Photographs, 1 Diagram, 3 Charts, 4 Graphs
Publication Year :
2010

Abstract

The Institute of Nuclear Energy Research (INER) in Taiwan had established a 100 kW HCPV power generation system in October, 2007. After operating for 16 months, the optical-electro conversion efficiency of the system downgraded from 23.5% to 20.7%. This report analyzes the root causes of HCPV module efficiency degradation and provides some solutions to overcome the problems. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
1277
Issue :
1
Database :
Complementary Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
54470045
Full Text :