Monitoring Off-Line and On-Line PD Under Impulsive Voltage on Induction Motors -- Part 1: Standard Procedure.
- Source :
- IEEE Electrical Insulation Magazine; Jul/Aug2010, Vol. 26 Issue 4, p16-26, 11p
- Publication Year :
- 2010
-
Abstract
- This article is the first of a series of three that examines the correlation between off-line and on-line measurements on Type I random-wound motors. The off-line tests reported in this first article were carried out according to IEC 60034-18-4 to demonstrate that they are PD free under impulsive voltage conditions. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 08837554
- Volume :
- 26
- Issue :
- 4
- Database :
- Complementary Index
- Journal :
- IEEE Electrical Insulation Magazine
- Publication Type :
- Academic Journal
- Accession number :
- 52809670