Back to Search Start Over

Improving an Unjustified Common Practice in Ex Post LMP Calculation.

Authors :
Fangxing Li
Yanli Wei
Adhikari, Sarina
Source :
IEEE Transactions on Power Systems; May2010, Vol. 25 Issue 2, p1195-1197, 3p
Publication Year :
2010

Abstract

A common practice for the Ex Post LMP calculation at a number of U.S. ISOs uses a small constant range, typically from -2.0 to +0.1 MW, as each generator's lower and upper bounds. This paper shows that this is an unjustified practice as the marginal units and LMP may change if the bounds are changed. A simple yet effective improvement is proposed. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
08858950
Volume :
25
Issue :
2
Database :
Complementary Index
Journal :
IEEE Transactions on Power Systems
Publication Type :
Academic Journal
Accession number :
50995345
Full Text :
https://doi.org/10.1109/TPWRS.2009.2037518