Back to Search
Start Over
Experimental study of effects of one kind of tangentially non-uniform tip clearance on the flow field at an exit of a compressor cascade passage.
- Source :
- Journal of Thermal Science; Mar2010, Vol. 19 Issue 1, p7-13, 7p
- Publication Year :
- 2010
-
Abstract
- This paper presents an experimental investigation of effects of one kind of tangentially non-uniform tip clearance on the flow field at an exit of a compressor cascade passage. The tests were performed in a low-speed large-scale cascade with the uniform tip clearance and the non-uniform clearance. The three-dimensional flow field was measured at the exit at three incidence angles of 0°, 5°, and 8° using a mini five-hole pressure probe. The measurement results show that the non-uniform tip clearance can moderate the leakage flow and blow down more low-energy fluids at the tip corner and decrease the accumulation of low-energy fluids which cause the flow blockage in the blade passage. In the meantime, the non-uniform clearance can weaken the tangential migration of the low-energy fluids in the endwall boundary layer and reduce the secondary loss and the flow blockage in the tip region. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 10032169
- Volume :
- 19
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- Journal of Thermal Science
- Publication Type :
- Academic Journal
- Accession number :
- 50122559
- Full Text :
- https://doi.org/10.1007/s11630-010-0007-7