Back to Search Start Over

Distal Airway Function Assessed by Oscillometry at Varying Respiratory Rate: Comparison with Dynamic Compliance.

Authors :
Oppenheimer, Beno W.
Goldring, Roberta M.
Berger, Kenneth I.
Source :
COPD: Journal of Chronic Obstructive Pulmonary Disease; Jun2009, Vol. 6 Issue 3, p162-170, 9p, 1 Chart, 6 Graphs
Publication Year :
2009

Abstract

Distal airways disease causes significant morbidity yet remains insufficiently identified. We hypothesize that: (1) when spirometry is normal impulse oscillometry may provide information about mechanical properties of the distal airways in a manner comparable to dynamic compliance and (2) variation of breathing frequency will influence oscillometric measurements similar to effects of breathing frequency on dynamic compliance. Fifty-three symptomatic subjects with normal large airway function (spirometry) were studied; distal airway dysfunction was identified by presence of frequency dependence of compliance (FDC). Oscillometric parameters evaluated were resistance at 20 Hz (R20) and 5-20 Hz (R5 - 20), reactance at 5Hz (X5), and reactance area (AX). R20 correlated with airway resistance by esophageal manometry (r = 0.74, p< 0.001); X5 correlated with dynamic compliance at a respiratory rate of 60bpm (r = 0.61, p< 0.001); R5-20 and AX correlated with FDC (r = 0.48, p< 0.001; r = 0.53, p< 0.01). IOS indices were further evaluated at increased respiratory rate (RR40). Oscillometric parameters changed minimally at RR40 in normal subjects ΔR20 = 0.20 = 0.08 cmH2O/L/s, ΔR5-20 = 0.10 ± 0.03 cmH2O/L/s, Δ AX = 0.33 ± 0.19 cmH2O/L). However, in symptomatic subjects, while R20 increased minimallyat RR40 (Δ R20 = 0.37 ± 0.10 cmH2O/L/s), R5 - 20 and AX increased markedly (Δ R5 - 20 = 0.54 ± 0.06 cmH2O/L/s, Δ AX = 4.28 ± 0.67 cmH2O/L) and reversed post bronchodilator. IOS evaluates physiology of the distal airways in a manner comparable to dynamic compliance. Elevated respiratory rate influences oscillometric parameters and must be considered when interpreting oscillometric data. IOS provides a non-invasive tool for assessment of distal airway function when spirometry is normal, which can be applied to various clinical settings including early diagnosis of COPD (GOLD stage 0), asthma in clinical remission and occupational/ environmental irritant exposure. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
15412555
Volume :
6
Issue :
3
Database :
Complementary Index
Journal :
COPD: Journal of Chronic Obstructive Pulmonary Disease
Publication Type :
Academic Journal
Accession number :
40627816
Full Text :
https://doi.org/10.1080/15412550902918410