Back to Search Start Over

Dynamic C-V characteristic for a varactor load connected with a transmission line.

Authors :
Watanabe, Takemi
Sangkrasin, Apiruk
Matsumoto, Fujihiko
Noguchi, Yasuaki
Source :
Electrical Engineering in Japan; Jun2009, Vol. 167 Issue 4, p32-38, 7p, 3 Diagrams, 9 Graphs
Publication Year :
2009

Abstract

Crosstalk is induced by a reflected wave of a load connected with a transmission line. Thus, analysis of the reflected wave is important. The reflected wave generated from a nonlinear load is complicated. In order to estimate the complicated reflected wave, we measured the reflected and incident waves for the nonlinear load and estimated the dynamic C-V characteristic, which explains the relation between the incident and reflected waves. This paper reports a simple experimental method of extracting reflected waves at a varactor load and presents estimates of the dynamic C-V characteristic of the load. It is shown that the reflected voltage waves simulated using the dynamic C-V characteristic agree with the measured results. © 2009 Wiley Periodicals, Inc. Electr Eng Jpn, 167(4): 32–38, 2009; Published online in Wiley InterScience (<URL>www.interscience.wiley.com</URL>). DOI 10.1002/eej.20821 [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
04247760
Volume :
167
Issue :
4
Database :
Complementary Index
Journal :
Electrical Engineering in Japan
Publication Type :
Academic Journal
Accession number :
37561722
Full Text :
https://doi.org/10.1002/eej.20821