The relative test performance characteristics of two commercial assays for the detection of Mycobacterium tuberculosis complex in paraffin-fixed human biopsy specimens.

Authors :
Drews, Steven J.
Eshaghi, AliReza
Pyskir, Daria
Chedore, Pam
Lombos, Ernesto
Broukhanski, George
Higgins, Rachel
Fisman, David N.
Blair, Joanne
Jamieson, Frances
Source :
Diagnostic Pathology; 2008, Vol. 3, Special section p1-4, 4p, 1 Chart
Publication Year :
2008

Abstract

The Seeplex™ TB Detection-2 assay (Rockville, MD) is a nested endpoint PCR for the Mycobacterium tuberculosis complex (MTBC) targets IS6110 and MPB64 that utilizes dual priming oligonucleotide technology. When used to detect the presence of MTBC DNA in formalin-fixed paraffin-embedded tissue specimens, the sensitivity and specificity of this assay is equivalent to a labor-intensive traditional endpoint PCR assay and is more sensitive than a commercial real-time PCR assay. [ABSTRACT FROM AUTHOR]