Abstract

The aim of any device designed for liver resection is to allow blood saving and quick resections. This may be optimized using a minimally invasive approach. A radiofrequency-assisted device is described that combines a cooled blunt-tip electrode with a sharp blade on one side in an in vivo preliminary study using hand-assisted laparoscopy to perform partial hepatectomies. Eight partial hepatectomies were performed on pigs with hand-assisted laparoscopy using the radiofrequency-assisted device as the only method for transection and hemostasis. The main outcome measures were transection time, blood loss, transection area, transection speed, blood loss per transection area, and tissue coagulation depth. The risk for biliary leak also was assessed using the methylene blue test. The transection time was 13 ± 7 min for a mean transected area of 34 ± 11 cm<superscript>2</superscript>. The mean total blood loss was 26 ± 34 ml. The mean transection speed was 3 ± 1 cm<superscript>2</superscript>/min, and the blood loss per transection area was 1 ± 1 ml/cm<superscript>2</superscript>. Abdominal examination showed no complications in nearby organs. One biliary leak was identified in one case using the methylene blue test. The transection surface was 34 ± 11 cm<superscript>2</superscript>, and the mean tissue coagulation depth was 9 ± 2 mm. The inviability of the coagulated surface was assessed by adenine dinucleotide (NADH) staining. The radiofrequency-assisted device has shown with a laparoscopic approach that it can perform liver resections faster and with less blood loss using a single device in a minimally invasive manner without vascular control than other commercial devices. The results show no significant differences with the same device used in an open procedure. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
18666817
Volume :
22
Issue :
5
Database :
Complementary Index
Journal :
Surgical Endoscopy & Other Interventional Techniques
Publication Type :
Academic Journal
Accession number :
31811709
Full Text :
https://doi.org/10.1007/s00464-008-9793-3