Back to Search Start Over

A case study on the effect of water from groundwater sources on indoor radon levels.

Authors :
Yasouka, Y.
Ishikawa, T.
Tokonami, S.
Takahashi, H.
Narazaki, Y.
Sinogi, M.
Source :
Journal of Radioanalytical & Nuclear Chemistry; Jan2008, Vol. 275 Issue 1, p165-172, 8p, 1 Diagram, 2 Charts, 4 Graphs
Publication Year :
2008

Abstract

Indoor airborne radon concentration released from water was estimated over several months based on experimental measurements. When heated water including radon was used, the radon level became high in the entire house. Filling the bathtub with hot water had a strong effect on the indoor radon level. In winter, the indoor radon concentration was high due to windows being closed. The radon transfer coefficient was estimated 2.5·10<superscript>−4</superscript> in this test house. This is 2.5 times higher than the average radon transfer efficiency estimated by UNSCEAR. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02365731
Volume :
275
Issue :
1
Database :
Complementary Index
Journal :
Journal of Radioanalytical & Nuclear Chemistry
Publication Type :
Academic Journal
Accession number :
28001006
Full Text :
https://doi.org/10.1007/s10967-007-6956-y