Back to Search Start Over

ITER-Like Antenna electrical performance.

Authors :
Argouarch, A.
Brémond, S.
Lombard, G.
Millon, L.
Mollard, P.
Volpe, D.
Vulliez, K.
Source :
AIP Conference Proceedings; 9/15/2007, Vol. 933 Issue 1, p127-130, 4p, 3 Diagrams, 2 Charts
Publication Year :
2007

Abstract

The future integration on Tore Supra (TS) of the new Ion Cyclotron Heating (ICRH) ITER-like prototype antenna will be performed to achieve the final validation within plasma conditions. Along the few years of developments and electrical optimizations, this antenna went through series of thermo/mechanical and electrical tests. This paper presents the latest electrical results of the ITER Like antenna under vacuum condition inside the test bed. High RF power (60 kW) for 2 seconds pulses were performed, the paper present the first electrical performance results and focused on the experimental measurements of the current monitoring compared to electrical simulations. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
933
Issue :
1
Database :
Complementary Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
26887802
Full Text :
https://doi.org/10.1063/1.2800457