Back to Search Start Over

36-segmented high magnetic field hexapole magnets for electron cyclotron resonance ion source.

Authors :
Sun, L. T.
Zhao, H. W.
Zhang, Z. M.
Wang, H.
Ma, B. H.
Zhang, X. Z.
Li, X. X.
Feng, Y. C.
Li, J. Y.
Guo, X. H.
Shang, Y.
Zhao, H. Y.
Source :
Review of Scientific Instruments; May2007, Vol. 78 Issue 5, p053302, 8p, 8 Diagrams, 3 Charts, 4 Graphs
Publication Year :
2007

Abstract

Two high magnetic field hexapoles for electron cyclotron resonance ion source (ECRIS) have successfully fabricated to provide sufficient radial magnetic confinement to the ECR plasma. The highest magnetic field at the inner pole tip of one of the magnets exceeds 1.5 T, with the inner diameter (i.d.)=74 mm. The other hexapole magnet provides more than 1.35 T magnetic field at the inner pole tip, and the i.d. is 84 mm. In this article, we discuss the necessity to have a good radial magnetic field confinement and the importance of a Halbach hexapole to a high performance ECRIS. The way to design a high magnetic field Halbach structure hexapole and one possible solution to the self-demagnetization problem are both discussed. Based on the above discussions, two high magnetic field hexapoles have been fabricated to be utilized on two high performance ECRISs in Lanzhou. The preliminary results obtained from the two ECR ion sources are given. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00346748
Volume :
78
Issue :
5
Database :
Complementary Index
Journal :
Review of Scientific Instruments
Publication Type :
Academic Journal
Accession number :
25684757
Full Text :
https://doi.org/10.1063/1.2740147