Back to Search Start Over

Electronics and Algorithms for HOM Based Beam Diagnostics.

Authors :
Frisch, Josef
Baboi, Nicoleta
Eddy, Nathan
Nagaitsev, Sergei
Hensler, Olaf
McCormick, Douglas
May, Justin
Molloy, Stephen
Napoly, Olivier
Paparella, Rita
Petrosyan, Lyudvig
Ross, Marc
Simon, Claire
Smith, Tonee
Source :
AIP Conference Proceedings; 2006, Vol. 868 Issue 1, p313-324, 12p, 4 Diagrams, 7 Graphs
Publication Year :
2006

Abstract

The signals from the Higher Order Mode (HOM) ports on superconducting cavities can be used as beam position monitors and to do survey structure alignment. A HOM-based diagnostic system has been installed to instrument both couplers on each of the 40 cryogenic accelerating structures in the DESY TTF2 Linac. The electronics uses a single stage down conversion from the 1.7 GHz HOM spectral line to a 20MHz IF which has been digitized. The electronics is based on low cost surface mount components suitable for large scale production. The analysis of the HOM data is based on Singular Value Decomposition. The response of the OM modes is calibrated using conventional BPMs. © 2006 American Institute of Physics [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
0094243X
Volume :
868
Issue :
1
Database :
Complementary Index
Journal :
AIP Conference Proceedings
Publication Type :
Conference
Accession number :
23289373