Back to Search Start Over

Partial Discharges Phenomenon in High Voltage Power Modules.

Authors :
Lebey, Th.
Malec, D.
Dinculescu, S.
Costan, V.
Breit, France F.
Dutarde, E.
Source :
IEEE Transactions on Dielectrics & Electrical Insulation; Aug2006, Vol. 13 Issue 4, p810-819, 10p, 6 Black and White Photographs, 4 Diagrams, 1 Chart, 6 Graphs
Publication Year :
2006

Abstract

Partial discharges measurements have been performed on 3.3 kV IGBT power modules. Results using both the normalized and a new proposed test are compared. The new test, allowing the detection of partial discharges in all the insulating materials, is detailed. Elementary defect patterns are used to distinguish the main cause (dies or insulating materials) of the observed partial discharges in IGBT modules. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
10709878
Volume :
13
Issue :
4
Database :
Complementary Index
Journal :
IEEE Transactions on Dielectrics & Electrical Insulation
Publication Type :
Academic Journal
Accession number :
22064936
Full Text :
https://doi.org/10.1109/TDEI.2006.1667740