Back to Search Start Over

The Efficiency of Thermal Neutron Detection and Collimation With Microchannel Plates of Square and Circular Geometry.

Authors :
Tremsin, Anton S.
Feller, W. Bruce
Downing, R. Gregory
Mildner, David F. R.
Source :
IEEE Transactions on Nuclear Science; Oct2005 Part 3, Vol. 52 Issue 5, p1739-1744, 6p
Publication Year :
2005

Abstract

Detectors with microchannel plates (MCPs) are currently widely used in photon and charged particle detection with high spatial (∼10 μm) and temporal (<0.5 ns) resolution. All the advances in MCP detection technologies can be successfully implemented for the detection of thermal neutrons by using MCPs manufactured from a modified glass mixture doped with neutron absorbing atoms. In this paper, we compare the efficiency of thermal neutron detection for two standard MCP geometries: circular-pore and square-pore MCPs doped with the <superscript>10</superscript>B isotope. The results of our modeling indicate that the detection of thermal neutrons with a square-pore MCP is 11%-23% more efficient than for the circular geometry, and can be higher than 70% for the existing MCP technology. [ABSTRACT FROM AUTHOR]

Details

Language :
Slovak
ISSN :
00189499
Volume :
52
Issue :
5
Database :
Complementary Index
Journal :
IEEE Transactions on Nuclear Science
Publication Type :
Academic Journal
Accession number :
19314446
Full Text :
https://doi.org/10.1109/TNS.2005.856621