Back to Search Start Over

MICRODOSIMETRY TEST ON DOUBLE LAYER BEAM SHAPING ASSEMBLY NEUTRON BEAM AS A BORON NEUTRON CAPTURE THERAPY NEUTRON SOURCE USING PHITS CODE.

Authors :
Bilalodin
Haryadi, A.
Sehah
Zusfahair
Sardjono, Y.
Tursinah, R.
Source :
Nuclear Physics & Atomic Energy; 2024, Vol. 25 Issue 4, p388-393, 6p
Publication Year :
2024

Abstract

A microdosimetry test on a double layer beam shaping assembly (DLBSA) neutron beam has been carried out using the particle and heavy ion transport code system (PHITS). The test aims to understand the mechanism of interactions between neutrons and microcells and to determine the linear energy transfer (LET) and the relative biological effectiveness (RBE) values of the DLBSA neutron beam. The test was carried out by interacting a neutron beam with microcells containing <superscript>10</superscript>B using a boron concentration of 70 ppm. The neutron source used comes from a 30 MeV cyclotron-based DLBSA. The simulation results show that the interaction of neutrons with microcells occurs through scattering, reflection, and absorption reaction mechanisms. The results of the microdosimetry test showed that the peak LET value of α-particles was 100 keV/μm and <superscript>7</superscript>Li was 200 keV/μm, with an RBE value for α of 9.83 and <superscript>7</superscript>Li of 6.11. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
1818331X
Volume :
25
Issue :
4
Database :
Complementary Index
Journal :
Nuclear Physics & Atomic Energy
Publication Type :
Academic Journal
Accession number :
182083907
Full Text :
https://doi.org/10.15407/jnpae2024.04.388