Back to Search
Start Over
The Panflute Technique: Novel 3D-Printed Patient Specific Instrumentation to Guide Curved Intra-Articular Osteotomies for Tibial Plateau Malunions.
- Source :
- Journal of Clinical Medicine; Oct2024, Vol. 13 Issue 20, p6175, 10p
- Publication Year :
- 2024
-
Abstract
- Background/Objectives: 3D patient-specific corrective osteotomies are optimized for use with oscillating saws, thereby rendering it incapable of executing curved osteotomies. The aim of this technical note is to introduce and evaluate the Panflute technique, which facilitates curved osteotomies with precise depth control for intra-articular corrective osteotomies in posttraumatic tibial plateau malunions. Methods: A 33-year-old male patient with an intra-articular malunion was treated one year after index surgery of a lateral split-depression tibial plateau fracture with the Panflute technique. The guide design allowed for multiple drill trajectories in a curved path, recreating the original fracture lines. Cylindrical drill tubes in the guide were tailored to match bone trajectory length. This resulted in a patient-specific Panflute-like design enabling precise depth control, safeguarding posterior neurovascular structures. Secondly, the recreated fragment was reduced with a reduction guide, applied to the plate in situ, to facilitate reposition using the plate as tool and reference. Results: The procedure went without technical drawbacks or surgical complications. Postoperative assessment showed that repositioning of the osteotomized articular fragment was performed accurately: pre- to postoperative translational corrections were 5.4 to 0.5 mm posterior displacement for AP deformity (x-axis); 2.9 to 1.0 mm lateral to medial reduction (y-axis); and 5.9 to 0.6 mm cranial-caudal correction (z-axis). Clinically, at 3 months, the fracture united, the patient regained full flexion, and valgus defect-laxity resolved. Conclusions: The presented Panflute-osteotomy guide allows for a pre-planned curved osteotomy. Additionally, for every drill trajectory, the depth could be controlled. The proposed method may expand our surgical armamentarium of patient-specific 3D techniques and solutions for complex intra-articular osteotomies. [ABSTRACT FROM AUTHOR]
- Subjects :
- TIBIAL plateau fractures
SURGICAL complications
OSTEOTOMY
SAWS
TUBES
Subjects
Details
- Language :
- English
- ISSN :
- 20770383
- Volume :
- 13
- Issue :
- 20
- Database :
- Complementary Index
- Journal :
- Journal of Clinical Medicine
- Publication Type :
- Academic Journal
- Accession number :
- 180526903
- Full Text :
- https://doi.org/10.3390/jcm13206175