Synthesis of novel N-substituted tetrabromophthalic as corrosion inhibitor and its inhibition of microbial influenced corrosion in cooling water system.

Authors :
Vignesh, Krishnan
Sujithra, Sankar
Vajjiravel, Murugesan
Narenkumar, Jayaraman
Das, Bhaskar
AlSalhi, Mohamad S.
Devanesan, Sandhanasamy
Rajasekar, Aruliah
Malik, Tabarak
Source :
Scientific Reports; 10/25/2024, Vol. 14 Issue 1, p1-18, 18p
Publication Year :
2024

Abstract

This study investigates the efficacy of newly synthesized inhibitor with a dual function of corrosion inhibition and biocide for control of microbial influenced corrosion (MIC) in carbon steel API 5LX in the cooling tower water (CTW) environment. Four types of N-substituted tetrabromophthalic inhibitor (N-TBI) were synthesized, and the structural characterization was performed via proton nuclear magnetic resonance spectroscopy, thermogravimetric analysis and high-resolution mass spectrometry. These studies revealed the distinctive optical, thermal, and dielectric properties of the synthesized inhibitors. The corrosion inhibition efficiency has been evaluated by the weight loss (WL) analysis and electrochemical measurements (ECM) and biofilm assay. Biofilm assays and WL showed that inhibitor II exhibited the highest inhibition efficiency 74% and 79% respectively than others. Further ECM showed that the higher charge transfer resistance and the lower corrosion current, suggesting a protective film formed on the metal surface which was due to the adsorption of the N-TBI. Fourier transform infrared spectroscopy confirmed the adsorption of the N-TBI as C–O stretching and C–H bending with the Fe complex. X-ray diffractometer revealed that the presence of inhibitors in the corrosion product (Fe<subscript>3</subscript>O<subscript>4</subscript>, Fe<subscript>2</subscript>O<subscript>3</subscript>, FeH<subscript>2</subscript>O<subscript>2</subscript>, FeS) were highly reduced than the control system. Overall, this study highlighted the potential application of N-TBI with dual function of corrosion inhibition and biocide to control the MIC for carbon steel API 5LX used in the CTW environment. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20452322
Volume :
14
Issue :
1
Database :
Complementary Index
Journal :
Scientific Reports
Publication Type :
Academic Journal
Accession number :
180497358
Full Text :
https://doi.org/10.1038/s41598-024-76254-8