Back to Search Start Over

Relative biological effectiveness of clinically relevant photon energies for the survival of human colorectal, cervical, and prostate cancer cell lines.

Authors :
Li, Joanna
Chabaytah, Naim
Babik, Joud
Behmand, Behnaz
Bekerat, Hamed
Connell, Tanner
Evans, Michael
Ruo, Russell
Vuong, Te
Abbasinejad Enger, Shirin
Source :
Physics in Medicine & Biology; 10/21/2024, Vol. 69 Issue 20, p1-15, 15p
Publication Year :
2024

Abstract

Objective. Relative biological effectiveness (RBE) differs between radiation qualities. However, an RBE of 1.0 has been established for photons regardless of the wide range of photon energies used clinically, the lack of reproducibility in radiobiological studies, and outdated reference energies used in the experimental literature. Moreover, due to intrinsic radiosensitivity, different cancer types have different responses to radiation. This study aimed to characterize the RBE of clinically relevant high and low photon energies in vitro for three human cancer cell lines: HCT116 (colon), HeLa (cervix), and PC3 (prostate). Approach. Experiments were conducted following dosimetry protocols provided by the American Association of Physicists in Medicine. Cells were irradiated with 6 MV x-rays, an <superscript>192</superscript>Ir brachytherapy source, 225 kVp and 50 kVp x-rays. Cell survival post-irradiation was assessed using the clonogenic assay. Survival fractions were fitted using the linear quadratic model, and survival curves were generated for RBE calculations. Main results. Cell killing was more efficient with decreasing photon energy. Using 225 kVp x-rays as the reference, the HCT116 RBE<subscript>SF0.1</subscript> for 6 MV x-rays, <superscript>192</superscript>Ir, and 50 kVp x-rays were 0.89 ± 0.03, 0.95 ± 0.03, and 1.24 ± 0.04; the HeLa RBE<subscript>SF0.1</subscript> were 0.95 ± 0.04, 0.97 ± 0.05, and 1.09 ± 0.03, and the PC3 RBE<subscript>SF0.1</subscript> were 0.84 ± 0.01, 0.84 ± 0.01, and 1.13 ± 0.02, respectively. HeLa and PC3 cells had varying radiosensitivity when irradiated with 225 and 50 kVp x-rays. Significance. This difference supports the notion that RBE may not be 1.0 for all photons through experimental investigations that employed precise dosimetry. It highlights that different cancer types may not have identical responses to the same irradiation quality. Additionally, the RBE of clinically relevant photons was updated to the reference energy of 225 kVp x-rays. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
00319155
Volume :
69
Issue :
20
Database :
Complementary Index
Journal :
Physics in Medicine & Biology
Publication Type :
Academic Journal
Accession number :
180117324
Full Text :
https://doi.org/10.1088/1361-6560/ad7d5a