Back to Search Start Over

Rapid and accurate determination of chlorine isotopic ratios with ICP-MS/MS using O2 reaction gas.

Authors :
Schlieder, Tyler D.
Rocco, Nicole D.
Laura di Vacri, Maria
Arnquist, Isaac J.
Bottenus, Danny
Huber, Zachary
McNamara, Bruce
Source :
JAAS (Journal of Analytical Atomic Spectrometry); Oct2024, Vol. 39 Issue 10, p2502-2507, 6p
Publication Year :
2024

Abstract

Chlorine isotopic ratio measurements are useful for stable isotope tracing, isotopic abundance measurements in nuclear chemistry, and accurate determination of concentrations using isotope dilution methods. Accurate and precise determination of Cl isotopic ratios using inductively coupled plasma mass spectrometry (ICP-MS) methods is challenging due to major polyatomic interferences of <superscript>16</superscript>O<superscript>18</superscript>O¹H<superscript>+</superscript> and <superscript>36</superscript>Ar¹H<superscript>+</superscript> on <subscript>35</subscript>Cl<subscript>+</subscript> and <subscript>37</subscript>Cl<subscript>+</subscript>, respectively. Previous work has demonstrated that using tandem mass spectrometry (ICP-MS/MS) with either H<subscript>2</subscript> or O<subscript>2</subscript> gas in the collision/reaction cell can significantly improve the precision, but not necessarily the accuracy, of chlorine isotopic measurements over single-quadrupole techniques. In this work, we further investigate ICP-MS/MS, using O<subscript>2</subscript> as a reaction gas, as a technique for accurate determination of Cl isotopic ratios. Using the methodology developed herein we measure both natural and enriched chlorine isotopic ratios in diverse samples matrices, targeting <superscript>37</superscript>Cl isotope enrichment efforts, without the need for complex front-end chemistry (i.e., ion exchange chromatography), while maintaining a typical accuracy and precision better than ~1%. The reduced need for time-consuming sample processing afforded by this method results in higher sample throughput (>80 measurements/day) relative to other analytical techniques (e.g., thermal ionization mass spectrometry, accelerator mass spectrometry, etc.). This work demonstrates that ICPMS/MS with O<subscript>2</subscript> as a reaction gas can be a useful tool for making rapid and accurate chlorine isotopic ratio measurements. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
02679477
Volume :
39
Issue :
10
Database :
Complementary Index
Journal :
JAAS (Journal of Analytical Atomic Spectrometry)
Publication Type :
Academic Journal
Accession number :
180064604
Full Text :
https://doi.org/10.1039/d4ja00191e