Back to Search
Start Over
Individualized C1-2 intra-articular three-dimensional printed porous titanium alloy cage for craniovertebral deformity.
- Source :
- Journal of Orthopaedic Surgery & Research; 9/16/2024, Vol. 19 Issue 1, p1-8, 8p
- Publication Year :
- 2024
-
Abstract
- Background: Congenital craniovertebral deformity, including basilar invagination (BI) and atlantoaxial instability (AAI), are often associated with three-dimensional (3D) deformity, such as C1-2 rotational deformity, craniocervical kyphosis, C1 lateral inclination, among other abnormalities. Effective management of these conditions requires the restoration of the 3D alignment to achieve optimal reduction. Recently, 3D printing technology has emerged as a valuable tool in spine surgery, offering the significant advantage of allowing surgeons to customize the prosthesis design. This innovation provides an ideal solution for precise 3D reduction in the treatment of craniovertebral deformities. Objective: This study aims to describe our approach to individualized computer-simulated reduction and the design of C1-2 intra-articular 3D printed porous titanium alloy cages for the quantitative correction of craniovertebral junction deformities. Methods: A retrospective analysis was conducted on patients with craniovertebral deformities treated at our institution using individualized 3D-printed porous titanium alloy cages. Preoperative CT data were used to construct models for 3D realignment simulations. Cage designs were tailored to the simulated joint morphology following computer-assisted realignment. Preoperative and postoperative parameters were statistically analyzed. Results: Fourteen patients were included in the study, with a total of 28 3D-printed porous titanium alloy cages implanted. There were no cases of C2 nerve root resection or vertebral artery injury. All patients experienced symptom relief and stable implant fixation achieved in all cases. No implant-related complications were reported. Conclusion: The use of individualized computer-simulated reduction and the design of C1-2 intra-articular 3D printed porous titanium alloy cage facilitates precise 3D realignment in patients with craniovertebral deformities, demonstrating effectiveness in symptom relief and stability. [ABSTRACT FROM AUTHOR]
- Subjects :
- SPINAL nerve root surgery
CERVICAL vertebrae abnormalities
RESEARCH funding
BASILAR artery
NEUROSURGERY
ATLANTO-axial joint
TITANIUM
RETROSPECTIVE studies
ALLOYS
VERTEBRAL artery
ARTIFICIAL joints
MEDICAL records
ACQUISITION of data
STATISTICAL reliability
THREE-dimensional printing
CERVICAL vertebrae
Subjects
Details
- Language :
- English
- ISSN :
- 1749799X
- Volume :
- 19
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- Journal of Orthopaedic Surgery & Research
- Publication Type :
- Academic Journal
- Accession number :
- 179669261
- Full Text :
- https://doi.org/10.1186/s13018-024-05049-4