Back to Search
Start Over
Effectiveness Assessment of Bispectral Index Monitoring Compared with Conventional Monitoring in General Anesthesia: A Systematic Review and Meta‐Analysis.
- Source :
- Anesthesiology Research & Practice; 8/7/2024, Vol. 2024, p1-12, 12p
- Publication Year :
- 2024
-
Abstract
- Background and Objective. The Bispectral Index (BIS) is utilized to guide the depth of anesthesia monitoring during surgical procedures. However, conflicting results regarding the benefits of BIS for depth of anesthesia monitoring have been reported in numerous studies. The purpose of this meta‐analysis and systematic review was to assess the effectiveness of BIS for depth of anesthesia monitoring. Search Methods. A systematic search of Ovid‐MEDLINE, Cochrane, and PubMed was conducted from inception to April 20, 2023. Clinical trial registers and grey literature were also searched, and reference lists of included studies, as well as related review articles, were manually reviewed. Selection Criteria. The inclusion criteria were randomized controlled trials without gender or age restrictions. The control groups used conventional monitoring, while the intervention groups utilized BIS monitoring. The exclusion criteria included duplicates, reviews, animal studies, unclear outcomes, and incomplete data. Data Collection and Analysis. Two independent reviewers screened the literature, extracted data, and assessed methodological quality, with analyses conducted using R 4.0 software. Main Results. Forty studies were included. In comparison to the conventional depth of anesthesia monitoring, BIS monitoring reduced the postoperative cognitive dysfunction risk (RR = 0.85, 95% CI: 0.73∼0.99, P = 0.04), shortened the eye‐opening time (MD = −1.34, 95% CI: −2.06∼−0.61, P < 0.01), orientation recovery time (MD = −1.99, 95% CI: −3.62∼−0.36, P = 0.02), extubation time (MD = −2.54, 95% CI: −3.50∼−1.58, P < 0.01), and postanesthesia care unit stay time (MD = −7.11, 95% CI: −12.67∼−1.55, P = 0.01) and lowered the anesthesia drug dosage (SMD = −0.39, 95% CI: −0.63∼−0.15, P < 0.01). Conclusion. BIS can be used to effectively monitor the depth of anesthesia. Its use in general anesthesia enhances the effectiveness of both patient care and surgical procedures. [ABSTRACT FROM AUTHOR]
- Subjects :
- DRUG dosage
GREY literature
COGNITION disorders
OPERATIVE surgery
UNITS of time
Subjects
Details
- Language :
- English
- ISSN :
- 16876962
- Volume :
- 2024
- Database :
- Complementary Index
- Journal :
- Anesthesiology Research & Practice
- Publication Type :
- Academic Journal
- Accession number :
- 179482143
- Full Text :
- https://doi.org/10.1155/2024/5555481