Back to Search Start Over

An Evaluation of the Cytocompatibility of Endodontic Bioceramics in Human Periodontal-Ligament-Derived Cells.

Authors :
Aka, Asuka
Matsuura, Takashi
Yoshimura, Atsutoshi
Source :
Journal of Functional Biomaterials; Aug2024, Vol. 15 Issue 8, p231, 10p
Publication Year :
2024

Abstract

The present study evaluated the cytocompatibility of three endodontic bioceramics in human periodontal-ligament-derived cells (hPDLCs): MTA Repair HP (HP), MTA Flow White (F), and Nishika Canal Sealer BG multi (BG). In addition, we also evaluated the effect of the powder–liquid (paste) ratio of F and BG on cytocompatibility. Discs of endodontic bioceramics (diameter = 8 mm, thickness = 1 mm) were prepared with HP, F, and BG. hPDLCs obtained from extracted teeth and cultured for three to five passages were used in the experiment. The prepared discs were placed at the bottom of a 48-well plate, seeded with hPDLCs at 100,000 cells/well, cultured for 7 or 28 days, and subjected to a 3-[4,5-dimethylthiazol-2-yl]-2,5 diphenyl tetrazolium bromide assay. hPDLCs cultured without any discs were used as a negative control (NC) group. Discs made of F or BG mixed in three different consistencies were also used in this experiment. The absorbance values at days 7 and 28 were high in the order of HP > NC > BG > F. Furthermore, F or BG with higher consistency showed higher absorbance values. MTA Repair HP had the highest cytocompatibility among the three materials. Furthermore, it also showed that higher consistency improved cytocompatibility. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
20794983
Volume :
15
Issue :
8
Database :
Complementary Index
Journal :
Journal of Functional Biomaterials
Publication Type :
Academic Journal
Accession number :
179349342
Full Text :
https://doi.org/10.3390/jfb15080231