Back to Search
Start Over
Multi-average high-acceleration modified volumetric interpolated breath-hold examination (VIBE) for free-breathing multiphase contrast-enhanced liver MRI: a comparative study with breath-hold VIBE.
- Source :
- Acta Radiologica; Jul2024, Vol. 65 Issue 7, p735-743, 9p
- Publication Year :
- 2024
-
Abstract
- Background: Breath-hold volumetric interpolated breath-hold examination (BH-VIBE) of multiphase contrast-enhanced liver magnetic resonance imaging (MPCE-LMRI) requires good cooperative individuals to comply with multiple breath-holds. Purpose: To develop a free-breathing modified VIBE (FB-mVIBE) as a substitute of BH-VIBE in MPCE-LMRI. Material and Methods: We modified VIBE with a high acceleration factor (2 × 2) and four averages to produce the mVIBE scan. A total of 90 individuals (40 men; mean age = 54.6 ± 10.0 years) who had received MPCE-LMRI as part of a voluntary health check-up for oncology survey were enrolled. Each participant was scanned in four phases (pre-contrast, arterial phase, venous phase, and delay phase), and each phase had two sequential scans. To encounter the timing effect of contrast enhancement, three scan orders were designed: BH-VIBE and FB-mVIBE (group A, n = 30); BH-VIBE and FB-VIBE (group B, n = 30); and FB-mVIBE and BH-VIBE (group C, n = 30). The comparisons included the objective measurements and 25 visual-score by two abdominal radiologists independently. Results: Consistency between raters was observed for all three sequences (intraclass correlation coefficient [ICC] = 0.741–0.829). For rater 1, the mean scores of FB-mVIBE (23.67 ± 1.32) were equal to those of BH-VIBE (23.83 ± 1.98) in groups C and B (P = 0.852). The mean scores of FB-mVIBE (22.07 ± 3.02), but significantly higher than those of FB-VIBE (14.7 ± 3.41) in groups A and B (P <0.001). Similar scores were found for rater 2. The objective measurement of FB-mVIBE were equal to or higher than BH-VIBE and markedly superior to FB-VIBE. Conclusion: FB-mVIBE is a practical alternative to BH-VIBE for individuals who cannot cooperate with multiple breath-holds for MPCE-LMRI. [ABSTRACT FROM AUTHOR]
Details
- Language :
- English
- ISSN :
- 02841851
- Volume :
- 65
- Issue :
- 7
- Database :
- Complementary Index
- Journal :
- Acta Radiologica
- Publication Type :
- Academic Journal
- Accession number :
- 178804837
- Full Text :
- https://doi.org/10.1177/02841851231222607