Because of the possible harm that drugs may cause to the environment and public health, the discovery of pharmaceuticals in drinking water sources has drawn increasing attention. Pharmaceuticals such as atezolizumab (ATZ), a monoclonal antibody used to treat liver cancer, can enter water sources through a number of different routes. The design and development of a new electrochemical sensor for the detection of ATZ in water sources are presented in this research study. Gold nanoparticles (Au NPs) and an anti-Atezolizumab antibody (Ab) on a glassy carbon electrode (GCE) were used to develop the immunosensor. Differential pulse voltammetry was used to comprehensively examine the immunosensor's electrochemical characteristics. The immunosensor showed a broad concentration range of 0.001 to 2000 µg/mL and a low detection limit of 0.6 ng/mL. When the performance of the sensor was compared to other documented ATZ immunoassays, it demonstrated better performance because of its wide analytical range and low detection limit. The immunosensor's repeatability and stability were assessed as well; results revealed a significant 40-day stability period and a relative standard deviation of 4.13%. The immunosensor's distinct capacity to recognize ATZ validated its selectivity. Recovery experiments using human serum, urine, and drinking water samples were used to assess the immunosensor's feasibility; the range of recoveries was 90.00 to 99.40%. The results showed a strong correlation with the ATZ ELISA Assay Kit that is sold commercially. All things considered, the creation of this unique electrochemical sensor marks a substantial breakthrough in the fields of drug detection and environmental monitoring. This sensor could be used to quickly and accurately identify ATZ in water sources, assisting in maintaining the security of our water supply and safeguarding public health and the environment. [ABSTRACT FROM AUTHOR]

Details

Language :
English
ISSN :
21934126
Volume :
18
Issue :
7
Database :
Complementary Index
Journal :
Journal of Food Measurement & Characterization
Publication Type :
Academic Journal
Accession number :
178776236
Full Text :
https://doi.org/10.1007/s11694-024-02576-w