Back to Search
Start Over
Dislocated 4-haptic intraocular lens rescue with Gore-tex suture scleral re-fixation.
- Source :
- International Journal of Retina & Vitreous; 7/8/2024, Vol. 10 Issue 1, p1-7, 7p
- Publication Year :
- 2024
-
Abstract
- Background: Dislocated IOL exchange conventionally involves manipulation within the anterior chamber which risks secondary injury to anterior chamber structures. We describe and evaluate a 4-haptic IOL rescue technique that avoids entering the anterior chamber and thus minimizes post operative inflammation, astigmatism and recovery time relative to conventional IOL explantation and replacement techniques. Methods: Retrospective, non-randomized, interventional study of all patients undergoing 4-haptic IOL rescue performed by two independent vitreoretinal surgeons at a single UK centre over two years. Surgical technique: A limited peritomy is performed with four 25-gauge scleral ports placed to enable use of two forceps, an infusion and a chandelier. A further four 27-gauge sclerotomies are symmetrically placed on the nasal and temporal sclera at 3 mm from the limbus with a 5 mm vertical separation on either side. A pars plana vitrectomy is performed followed by chandelier illuminated, bimanual cleaning of the dislocated IOL using 27-gauge serrated forceps. Gore-tex sutures are threaded through the IOL islets within the vitreous cavity and externalized through the sclerotomies for scleral re-fixation followed by conjunctival closure. Results: Seven patients underwent IOL recycling with Gore-Tex suture scleral re-fixation. All procedures were successful in repositioning the IOLs, with all patients satisfied with post-operative outcome. Mean (standard deviation) time to IOL dislocation was 13 (3) years. Median visual acuity significantly improved post-operatively from 0.85 logMAR (Interquartile Range [IQR]: 0.2–2.1) to 0.07 (0.02–0.60) logMAR (p = 0.02). No significant post-operative complications were noted apart from persistent cystoid macular oedema in one patient non-compliant with post-operative treatment. Conclusions: Transscleral refixation using Gore-Tex suture is an effective, safe and practical approach in the management of dislocated 4-piece IOLs. [ABSTRACT FROM AUTHOR]
- Subjects :
- INTRAOCULAR lenses
SURGICAL complications
SUTURES
SUTURING
OPERATIVE surgery
FORCEPS
Subjects
Details
- Language :
- English
- ISSN :
- 20569920
- Volume :
- 10
- Issue :
- 1
- Database :
- Complementary Index
- Journal :
- International Journal of Retina & Vitreous
- Publication Type :
- Academic Journal
- Accession number :
- 178294767
- Full Text :
- https://doi.org/10.1186/s40942-024-00562-4