РОЗРАХУНОК РЕГУЛЮВАЛЬНИХ ХАРАКТЕРИСТИК РЕЗОНАНСНИХ ПЕРЕТВОРЮВАЧІВ МЕТОДОМ СУПЕРПОЗИЦІЇ.
- Source :
- Technical Electrodynamics / Tekhnichna Elektrodynamika; Jul/Aug2024, Issue 4, p24-33, 10p
- Publication Year :
- 2024
-
Abstract
- The work presents the calculations of the control characteristics of the full-bridge resonant converter with a series resonant LLC circuit and frequency control by two methods - the first harmonic method and the superposition method. The theoretical results were verified by the analytical-structural modeling method. The power circuit of the resonant converter for the analysis of electromagnetic processes is replaced by a linear T-shaped circuit with two series resonant RLC-circuits and equivalent generators of rectangular voltages, which simulate a transistor inverter and a diode rectifier in the quasi-continuous current mode. Analytical-structural modeling method consists in partly analytical and partly structural ways of building a numerical model of the resonant converter in the form of the simulation model in the MATLAB-Simulink environment. Linear structural links of the model are created on the basis of integral equations of circles. Non-linear links are created based on the non-linear functions and causal relationships. The structural model based on these links takes into account the nonlinearity of the elements of the power circuit of the resonant converter and is based on simpler mathematical expressions compared to the equivalent mathematical model of the resonant converter. The structural model corresponds to the idea of the resonant converter in the form of the resonant circuit with independent equivalent voltage generators and allows to adjust the magnetic coupling coefficient between the transformer windings and simulate processes with arbitrary control functions of equivalent generators. The peculiarity of the use of the superposition method for calculating the static characteristics of the resonant converter is the need to match the voltage phases of the equivalent generators of the equivalent circuit during the changes of the operating frequency or relative load voltage. The dependence of the input voltage of the rectifier, which is simulated by the second equivalent generator, on the processes of the power circuit of the real resonant converter, determines the conditions for matching (adjusting) the phases of the equivalent generators. References 30, figures 5. [ABSTRACT FROM AUTHOR]
Details
- Language :
- Ukrainian
- ISSN :
- 16077970
- Issue :
- 4
- Database :
- Complementary Index
- Journal :
- Technical Electrodynamics / Tekhnichna Elektrodynamika
- Publication Type :
- Academic Journal
- Accession number :
- 178258844
- Full Text :
- https://doi.org/10.15407/techned2024.04.024